Types of Overhead Conductors
Overhead conductors are essential components in electrical power transmission and distribution systems, designed to carry electricity across long distances with minimal losses. They come in various types, each engineered for specific applications based on efficiency, cost, mechanical strength, and environmental resilience. From widely used aluminum and copper to advanced hybrid and reinforced designs, selecting the right conductor involves balancing conductivity, weight, durability, and installation requirements.
Aluminum Conductors
The most widely used type due to their lightweight nature, cost-effectiveness, and strong performance in diverse conditions.
Advantages
- Lightweight – reduces structural support requirements
- Excellent corrosion resistance
- Good thermal conductivity
- Lower cost compared to copper
- Ideal for long-span installations
Limitations
- Lower conductivity than copper (about 61% IACS)
- Less tensile strength without reinforcement
- Greater thermal expansion under load
Best for: General power transmission, rural grids, and areas where weight and cost are key factors
Copper Conductors
Premium conductors known for superior electrical conductivity and reliability in high-demand environments.
Advantages
- Highest electrical conductivity among common metals (~100% IACS)
- High tensile strength and ductility
- Excellent performance in compact urban networks
- Durable and resistant to fatigue
Limitations
- Heavier than aluminum – requires stronger support structures
- More expensive material cost
- Prone to theft due to scrap value
- Vulnerable to corrosion in certain environments without coating
Best for: Urban power distribution, short-distance high-current applications, and settings where space is limited
Copper-Steel Reinforced Conductors
Engineered to combine the excellent conductivity of copper with the mechanical strength of steel for demanding applications.
Advantages
- High conductivity with enhanced tensile strength
- Suitable for long spans and heavy mechanical loads
- Improved sag resistance under high temperatures
- Ideal for harsh environments including coastal zones
Limitations
- Higher cost due to dual-material construction
- Increased weight affects installation logistics
- Steel core may corrode if not properly coated
Best for: Long-distance transmission lines, industrial zones, and regions with extreme weather or high wind loads
Hybrid & Specialized Conductors
Innovative solutions combining materials to optimize performance across multiple parameters.
Advantages
- Aluminum-Copper Hybrid: Balances conductivity, weight, and corrosion resistance
- ADSS Cables: All-dielectric self-supporting; no metallic components, ideal for communication and power co-location
- Tinned Copper: Enhanced corrosion protection for marine and industrial environments
- Mylar-Insulated: Fire-resistant and mechanically robust
Limitations
- More complex manufacturing process
- Limited availability and higher cost
- May require specialized installation techniques
Best for: Specialized infrastructure, coastal installations, hybrid power-communication networks, and fire-prone areas
Key Aluminum Alloys in Overhead Lines
One of the most notable aluminum alloys used in overhead conductors is Myral® 1350-H19 aluminum, which is commonly used in:
- ACSR (Aluminum Conductor Steel Reinforced): Combines aluminum strands with a steel core for strength
- ACSS (Aluminum Conductor Steel Supported): Operates at higher temperatures with improved sag performance
- OHGW (Overhead Ground Wire): Used for lightning protection and grounding in transmission towers
This alloy offers approximately 55% of the conductivity of copper while being significantly lighter and highly resistant to corrosion, making it ideal for extreme climates, coastal regions, and polluted industrial environments.
| Type | Conductivity | Weight | Durability | Best Application |
|---|---|---|---|---|
| Aluminum Conductors | Good (61% IACS) | Lightweight | High (corrosion-resistant) | Rural transmission, cost-sensitive projects |
| Copper Conductors | Excellent (100% IACS) | Heavy | Very High | Urban distribution, high-current circuits |
| Copper-Steel Reinforced | Excellent | Heavy | Exceptional (mechanical + electrical) | Long spans, coastal & industrial areas |
| Hybrid / Specialized | Variable | Medium to Heavy | High to Very High | Specialized networks, harsh environments |
Expert Tip: When selecting overhead conductors, always consider not only electrical performance but also environmental exposure, mechanical stress, and lifecycle costs. For coastal installations, prioritize corrosion-resistant materials like tinned copper or high-grade aluminum alloys with protective coatings.
Material & Durability of Overhead Conductors
Overhead conductors are engineered using durable, high-performance materials to ensure uninterrupted power transmission, operational efficiency, and long-term reliability. These conductors must withstand environmental stressors such as extreme temperatures, UV radiation, wind loading, and mechanical abrasion. Suppliers offer a range of standard and specialized materials tailored to specific electrical, mechanical, and economic requirements, balancing conductivity, strength, corrosion resistance, and cost.
Aluminum: Lightweight and Cost-Effective Conductor Material
Aluminum is the most widely used material in overhead power lines due to its favorable combination of light weight, good electrical conductivity, and affordability. Although it has only about 60% of the conductivity of copper, its low density (approximately one-third that of copper) allows for longer spans between support structures with reduced structural loading.
Modern aluminum conductors often feature enhanced designs such as All-Aluminum Alloy Conductor (AAAC) or Aluminum Conductor Steel-Reinforced (ACSR), which improve tensile strength and sag resistance. Additionally, many aluminum conductors are coated with a thin layer of mylar or polymer-based insulation to enhance dielectric performance, resist moisture ingress, and protect against abrasion and UV degradation—extending service life in exposed environments.
Copper: High Conductivity for Space-Constrained Applications
Copper remains the benchmark for electrical conductivity, making it ideal for applications where space and efficiency are critical. While heavier and more expensive than aluminum, copper conductors are sometimes used in urban power distribution networks or compact substations where high current capacity is needed within limited physical footprints.
To combat copper’s susceptibility to corrosion—especially in coastal or industrial environments—tinned copper variants are commonly employed. The tin coating acts as a protective barrier, significantly improving resistance to oxidation, sulfidation, and galvanic corrosion without compromising electrical performance. This makes tinned copper an excellent choice for harsh or chemically aggressive environments.
Copper-Steel Alloys: Strength Meets Conductivity
In high-tension and long-span applications—such as river crossings, mountainous terrain, or heavy-load transmission lines—mechanical strength becomes as important as electrical performance. Copper-steel alloys, particularly those used in Aluminum Conductor Steel-Reinforced (ACSR) or hybrid copper-steel core designs, combine the high tensile strength of steel with the conductive properties of copper or aluminum.
The steel core provides structural integrity and reduces sag under thermal expansion and mechanical load, while the outer layers carry the majority of the current. These composite conductors are especially valuable in regions prone to ice loading, high winds, or seismic activity, where conductor failure could lead to widespread outages and costly repairs.
Specialty Alloys and Advanced Materials
For specialized applications, engineers may specify advanced alloy materials to meet unique performance demands. Examples include:
Durability Factors in Overhead Conductors
The longevity of overhead conductors depends on their ability to endure multiple environmental and operational stressors:
- Temperature Extremes: Conductors expand when heated and contract when cooled. Repeated cycling can cause fatigue, especially at connection points.
- UV Exposure: Prolonged sunlight degrades polymer coatings and insulation unless UV-stabilized materials are used.
- Mechanical Stress: Wind-induced vibration (aeolian vibration), galloping, and ice loading can lead to strand breakage or fatigue failure over time.
- Corrosion: Moisture, salt spray, and pollutants accelerate oxidation, particularly in coastal or industrial zones.
ANSI M-795 Standard: Enhancing Conductor Longevity
The ANSI M-795 standard establishes rigorous performance criteria for overhead conductors, particularly regarding resistance to abrasion, impact, and environmental degradation. It mandates the use of a dielectric polymer sheath that acts as a multi-functional protective layer.
This sheath provides critical protection against:
- UV radiation – preventing embrittlement and cracking
- Temperature fluctuations – reducing thermal fatigue
- Mechanical damage – shielding against abrasion and impact from debris or wildlife
- Moisture and contaminants – minimizing corrosion and insulation breakdown
Compliance with ANSI M-795 significantly enhances conductor lifespan, reduces maintenance frequency, and improves system reliability—especially in extreme climates or remote installations where access for repairs is difficult and costly.
| Material Type | Conductivity | Tensile Strength | Corrosion Resistance | Best Use Case |
|---|---|---|---|---|
| Aluminum (AAC/AAAC) | Medium-High | Low-Medium | Good (with coating) | General overhead distribution lines |
| Copper (Tinned) | Very High | Medium | Excellent | Urban networks, corrosive environments |
| Copper-Steel Alloy | High | Very High | Good | Long spans, heavy loads, high-stress zones |
| Specialty Alloys (e.g., Ni-Cu, Al-Si) | Medium | High | Excellent | Extreme environments, high-temperature operations |
Important: Selecting the right conductor material involves a comprehensive evaluation of electrical load requirements, mechanical stresses, environmental conditions, and lifecycle costs. Using substandard materials or neglecting protective standards like ANSI M-795 can lead to premature failure, increased maintenance expenses, and safety hazards. Always consult engineering guidelines and local regulatory codes when specifying overhead conductors for new or upgraded power systems.
Commercial Uses of Overhead Conductors
Overhead conductors are essential components in modern infrastructure, enabling the efficient transmission of electricity and data across various commercial sectors. From powering cities to connecting remote regions, these conductors form the backbone of utility networks, renewable energy integration, telecommunications, and transportation systems. Their cost-effectiveness, scalability, and reliability make them a preferred choice over underground alternatives in many applications.
Utility Companies
Electric utilities rely heavily on overhead conductors for high-voltage transmission and medium-to-low voltage distribution networks. These systems deliver electricity from power plants to residential, commercial, and industrial consumers across vast geographic areas.
- Aluminum Conductors (AC): Widely used due to their excellent conductivity-to-weight ratio, corrosion resistance, and lower cost compared to copper.
- ACSR (Aluminum Conductor Steel Reinforced): Combines aluminum’s conductivity with steel’s tensile strength, ideal for long spans and high-load environments.
- AAAC (All-Aluminum Alloy Conductor): Offers superior corrosion resistance and strength, commonly used in coastal or chemically aggressive environments.
- High-Temperature Low-Sag (HTLS) Conductors: Enable increased power transfer without requiring new towers, supporting grid modernization and load growth.
Key Benefit: Overhead lines are easier and more economical to inspect, maintain, and repair than underground cables, minimizing service disruptions.
Renewable Energy Integration
As the world shifts toward sustainable energy, overhead conductors play a pivotal role in connecting remote renewable generation sites—such as wind farms, solar parks, and hydroelectric plants—to the main electrical grid.
- Wind Farms: Offshore and onshore installations use corrosion-resistant conductors (e.g., AAAC or trapezoidal wire designs) to transmit power over long distances with minimal losses.
- Solar Power Plants: Located in arid or remote regions, these facilities use durable, heat-resistant conductors capable of withstanding extreme temperatures and UV exposure.
- Hydroelectric Stations: Often situated in mountainous or isolated areas, they depend on robust overhead lines to transport large amounts of electricity efficiently.
- Grid Interconnection: Specialized conductors support asynchronous interties and HVDC (High-Voltage Direct Current) links between regional grids.
Sustainability Note: Efficient transmission reduces energy waste, enhancing the overall environmental benefits of renewable projects.
Telecommunications
Modern telecom infrastructure increasingly integrates power and data transmission through overhead conductor systems, especially in rural and underserved areas where trenching is impractical or too costly.
- Aerial Bundled Cables (ABC): Combine insulated power conductors with fiber-optic or copper communication lines, allowing dual-purpose deployment for electricity and broadband.
- Hybrid Conductors: Copper-steel reinforced or aluminum-clad steel wires provide mechanical strength and electrical continuity for cell tower grounding and signal integrity.
- Cell Tower Power Supply: Overhead copper or aluminum conductors deliver reliable primary and backup power to remote cellular base stations.
- Rural Connectivity: ABC systems enable telecom providers to extend both internet and electricity access simultaneously, improving digital inclusion.
Cost Advantage: Aerial installation can reduce deployment costs by up to 60% compared to underground cabling, accelerating service rollout.
Transportation Systems
Electrified transportation networks depend on overhead conductors to supply continuous power to trains, trams, and trolley buses, ensuring smooth and eco-friendly urban and intercity mobility.
- Electric Railways: Use copper or aluminum contact wires suspended above tracks to power locomotives via pantographs. These conductors must withstand constant friction, vibration, and weather extremes.
- Trams and Trolley Buses: Operate using overhead catenary systems with high-conductivity copper alloys that ensure consistent power delivery in stop-and-go urban environments.
- Third Rail Alternatives: In areas with safety or icing concerns, overhead lines are preferred over third-rail systems.
- High-Speed Rail: Requires advanced conductors with low electrical resistance and high mechanical stability to maintain performance at speeds exceeding 200 mph.
Efficiency Gain: Electrified public transit powered by overhead lines reduces reliance on fossil fuels and lowers operational emissions.
Industry Insight: The future of overhead conductors lies in smart grid integration, where sensors and monitoring devices are embedded within conductor systems to provide real-time data on temperature, tension, and fault detection. This enhances grid resilience, enables predictive maintenance, and supports the integration of distributed energy resources.
| Sector | Common Conductor Types | Key Performance Requirements | Typical Applications |
|---|---|---|---|
| Utility Power | ACSR, AAAC, AC, HTLS | High conductivity, mechanical strength, corrosion resistance | Transmission lines, distribution networks |
| Renewable Energy | AAAC, HTLS, Trapezoidal Conductors | Thermal stability, UV resistance, low sag | Wind farms, solar parks, hydro stations |
| Telecommunications | Aerial Bundled Cables (ABC), Copper-Steel Core | Dual power/data capability, durability, ease of installation | Rural broadband, cell tower power, hybrid networks |
| Transportation | Copper Contact Wires, Aluminum-Magnesium-Silicon Alloys | High conductivity, wear resistance, thermal endurance | Trams, electric trains, trolley buses |
Emerging Trends and Considerations
- Grid Modernization: Utilities are upgrading aging infrastructure with advanced conductors that increase capacity without new right-of-way acquisition.
- Environmental Resilience: Conductors with ice-phobic coatings and improved galvanic protection are being deployed in harsh climates.
- Digital Twin Integration: Real-time monitoring of conductor performance allows utilities to simulate stress conditions and optimize maintenance schedules.
- Regulatory Compliance: Adherence to IEEE, IEC, and NESC standards ensures safety, reliability, and interoperability across systems.
- Public Acceptance: While overhead lines are cost-effective, visual impact and electromagnetic field (EMF) concerns require careful community engagement during planning phases.
How To Choose Overhead Conductors: A Comprehensive Guide
Selecting the right overhead conductor is a crucial engineering decision that impacts the efficiency, reliability, and cost-effectiveness of power transmission and distribution systems. The ideal conductor balances electrical performance, mechanical strength, environmental resilience, and lifecycle costs. This guide explores the key factors in conductor selection, compares common materials, and provides practical recommendations for various applications.
Safety & Compliance Note: Always adhere to national and international standards (e.g., IEEE, IEC, NEC) when selecting and installing overhead conductors. Consult a licensed electrical engineer for system design and ensure compliance with local utility regulations and safety codes.
Key Factors in Overhead Conductor Selection
- Electrical Conductivity and Current-Carrying Capacity
Conductivity determines how efficiently a material transfers electrical current with minimal energy loss (I²R losses). Higher conductivity reduces voltage drop and improves system efficiency.
- Copper: Offers superior conductivity (approximately 100% IACS) and requires a smaller cross-sectional area for the same current load. Ideal for high-density urban power distribution and telecommunications where space is limited.
- Aluminum: Has about 61% of copper’s conductivity but is significantly lighter and more cost-effective. Requires a larger diameter to carry equivalent current, making it suitable for long-distance transmission lines where weight and cost are critical.
- Aluminum Alloys (e.g., AA-6201): Slightly lower conductivity than pure aluminum but enhanced mechanical strength, often used in ACSR (Aluminum Conductor Steel Reinforced) configurations.
- Cost Considerations: Initial vs. Lifecycle
Balancing upfront material costs with long-term performance is essential for economic efficiency.
- Copper has a higher initial cost but may offer lower lifetime costs in high-load applications due to reduced energy losses and longer service life.
- Aluminum is more economical initially and reduces structural support costs due to its lighter weight, making it ideal for rural or long-span installations.
- Consider total cost of ownership, including installation, maintenance, energy losses, and replacement intervals.
- Environmental and Corrosion Resistance
Environmental conditions significantly impact conductor longevity and performance.
- Coastal/Marine Environments: Salt spray accelerates corrosion. Aluminum naturally forms a protective oxide layer, offering better corrosion resistance than bare copper. For extreme marine conditions, use tinned copper or aluminum conductors with corrosion-resistant coatings.
- Industrial Areas: High pollution and chemical exposure require conductors with protective insulation or alloyed materials like aluminum-silicon.
- Extreme Temperatures: In very high or low temperatures, use conductors with polymer-insulated stainless steel supports or temperature-resistant alloys to prevent thermal expansion issues and brittleness.
- UV Exposure: Prolonged sunlight degrades some materials. UV-stabilized polymer jackets or metallic shielding are recommended for long-term outdoor exposure.
- Mechanical Strength and Durability
Overhead conductors must withstand mechanical stresses such as wind, ice loading, vibration, and physical impact.
- Copper-Steel Reinforced (e.g., CCS): Combines high conductivity with tensile strength, ideal for heavy-load spans or areas with frequent mechanical stress.
- ACSR (Aluminum Conductor Steel Reinforced): The most widely used conductor for transmission lines—aluminum strands carry the current while a steel core provides strength.
- Aluminum-Silicon Alloys: Offer excellent resistance to thermal and mechanical fatigue, making them suitable for high-vibration environments or renewable energy installations.
- Weight and Structural Impact
Lighter conductors reduce load on poles, towers, and insulators, lowering installation and support costs.
- Aluminum is about 30% the weight of copper for the same volume, making it ideal for long spans and remote installations.
- Reduced weight also lowers transportation and handling costs, especially in rugged terrain.
- Sustainability and Recyclability
Environmental responsibility is increasingly important in infrastructure projects.
- Copper is highly recyclable (up to 95% recovery rate) and retains its properties after recycling, making it a sustainable choice for long-term installations.
- Aluminum is also recyclable but requires more energy to produce from raw ore. However, recycled aluminum saves up to 95% of the energy needed for primary production.
- Manufacturers are increasingly adopting eco-friendly materials and production methods to meet sustainability goals.
- Application-Specific Requirements
Different applications demand tailored conductor solutions.
- Long-Distance Transmission: Prioritize lightweight, cost-effective conductors like ACSR or AAAC (All Aluminum Alloy Conductor) to minimize sag and support costs.
- Renewable Energy Farms (Solar/Wind): Use corrosion-resistant, thermally stable conductors such as aluminum-silicon alloys or tinned copper with protective jackets to handle variable loads and harsh outdoor conditions.
- Telecommunications & Sensitive Electronics: Copper is preferred due to its superior conductivity and ability to minimize electromagnetic interference (EMI), ensuring signal integrity.
| Conductor Type | Best For | Conductivity | Strengths | Limited Use Cases |
|---|---|---|---|---|
| Bare Copper | Urban distribution, telecom | High (~100% IACS) | Excellent conductivity, durability, recyclability | High cost, heavy, prone to theft |
| Aluminum (AAC) | Short to medium spans, low tension | Moderate (~61% IACS) | Lightweight, cost-effective, corrosion-resistant | Lower strength, prone to creep under load |
| ACSR | Long-span transmission lines | Moderate to High | High strength-to-weight ratio, economical | Galvanic corrosion risk if not coated |
| AAAC | Corrosive environments, coastal areas | Moderate | Superior corrosion resistance, good strength | Higher cost than AAC |
| Tinned Copper | Marine, high-humidity zones | High | Corrosion-resistant, reliable in harsh climates | Expensive, heavier than aluminum |
Expert Tip: For hybrid or evolving grids (e.g., integrating solar/wind), consider conductors with higher thermal ratings and corrosion resistance to accommodate future load increases and environmental variability. Conduct regular infrared thermography inspections to detect hotspots and prevent failures.
Best Practices for Conductor Selection
- Perform a site-specific assessment considering climate, load requirements, and existing infrastructure.
- Use software tools to model sag, tension, and clearance under various temperature and loading conditions.
- Specify conductors with appropriate insulation or shielding for EMI-sensitive areas.
- Consider future expansion—select conductors with margin for increased load.
- Work with reputable suppliers who provide certified materials with traceable quality assurance.
- Train installation crews on proper handling to avoid kinking or damaging conductors during deployment.
Choosing the right overhead conductor is not a one-size-fits-all decision. It requires a holistic evaluation of technical, economic, and environmental factors. By understanding the trade-offs between materials like copper, aluminum, and their alloys, engineers and project managers can design power systems that are efficient, reliable, and sustainable. When in doubt, consult industry standards and engage with experienced electrical engineers to ensure optimal performance and safety.
Frequently Asked Questions About Overhead Conductors
Q. What are overhead conductors?A. Overhead conductors are specialized cables suspended above ground—typically on utility poles or transmission towers—that carry electrical current across long distances for power transmission and distribution networks. These conductors are commonly made from materials like aluminum, copper, or steel, and sometimes feature composite designs such as aluminum-conductor steel-reinforced (ACSR) for enhanced performance. While "mylar cable" is not a standard term in power transmission (mylar is typically used in insulation or capacitors), the correct terminology includes types such as ACSR, all-aluminum conductor (AAC), and aluminum alloy conductor (AAAC), each suited to specific applications based on conductivity, weight, and strength requirements.
Q. What factors impact conductor selection?A. Selecting the right overhead conductor involves evaluating several critical engineering and environmental factors to ensure efficiency, safety, and longevity of the power system:
- Electrical Load Requirements: The amount of current (amperage) the conductor must carry determines its size and material. Higher loads may require larger cross-sectional areas or more conductive materials like copper or aluminum alloys.
- Mechanical Strength: Conductors must withstand mechanical stresses such as wind, ice loading, and tension over long spans. Steel-reinforced designs are often used in high-tension applications.
- Environmental Conditions: Exposure to moisture, salt (in coastal areas), industrial pollutants, and extreme temperatures affects material choice. Corrosion-resistant materials like aluminum or coated conductors are preferred in harsh climates.
- Thermal Performance: Conductors expand when heated; materials with low thermal sag are essential to maintain safe clearance from the ground and structures.
- Cost and Availability: Aluminum is widely used due to its favorable balance of conductivity, light weight, and lower cost compared to copper.
- Regulatory Standards: Compliance with national and international standards (e.g., IEEE, IEC, ASTM) ensures reliability and interoperability within the grid.
A. Corrosion resistance is vital for maintaining the structural integrity, electrical efficiency, and service life of overhead conductors. In environments such as coastal regions (with high salt content in the air) or industrial zones (with acidic pollutants), unprotected conductors can degrade rapidly. Corrosion leads to:
- Reduced cross-sectional area, increasing resistance and causing overheating.
- Weakened mechanical strength, raising the risk of breakage or failure under load.
- Poor electrical contact at splices and connections, leading to energy losses and potential hotspots.
Materials like aluminum naturally form a protective oxide layer, while steel cores in composite conductors are often galvanized or coated. Using corrosion-resistant alloys or protective coatings significantly extends the lifespan of transmission lines and reduces maintenance costs.
Q. Why are copper-steel conductors durable?A. While pure copper-steel conductors are rare in modern overhead lines, the concept likely refers to aluminum-conductor steel-reinforced (ACSR) cables, which combine the best properties of both metals. However, copper-clad steel conductors do exist in specialized applications such as grounding or communication lines. Their durability comes from:
- High Tensile Strength: Steel provides exceptional mechanical strength, allowing the conductor to span long distances between towers without excessive sag.
- Corrosion Resistance (when coated): Copper coating protects the steel core from rust and environmental degradation, especially in moist or chemically aggressive environments.
- Good Electrical Conductivity: Copper offers superior conductivity compared to aluminum or steel alone, making it effective for signal transmission or grounding systems.
- Thermal Stability: These conductors maintain performance under fluctuating temperatures and resist deformation over time.
In power transmission, ACSR is more common than copper-steel, but copper-reinforced designs are valued in applications where both conductivity and strength are essential, such as in rural electrification or railway overhead lines.
Q. What are the benefits of using aluminum conductors?A. Aluminum conductors are among the most widely used in overhead power systems due to their excellent combination of performance and cost-effectiveness. Key advantages include:
- Lightweight: Aluminum has about one-third the density of copper, reducing structural load on poles and towers and lowering installation costs.
- Excellent Corrosion Resistance: Forms a self-protecting oxide layer when exposed to air, making it ideal for outdoor and coastal environments.
- Lower Material Cost: Significantly cheaper than copper, enabling large-scale deployment in transmission and distribution networks.
- Good Conductivity: While not as conductive as copper, aluminum’s conductivity-to-weight ratio is favorable, especially in high-voltage transmission where current is lower.
- Versatility: Available in various configurations—such as AAC (all-aluminum), AAAC (aluminum alloy), and ACSR—allowing engineers to tailor solutions for specific needs.
Despite requiring larger diameters than copper for equivalent conductance, aluminum remains the preferred choice for most overhead lines due to its overall efficiency, durability, and economic advantages.