Types of Dental Bur Changers

A dental bur changer is a critical tool in modern dentistry that enables quick, safe, and efficient replacement of dental burs—the small cutting instruments used in drills. These devices are categorized by their operating mechanism into manual, semiautomatic, and automatic systems, each offering distinct advantages in terms of speed, precision, cost, and ease of use. Understanding the differences helps dental professionals choose the right system based on practice demands, workflow efficiency, and budget.

Manual Dental Bur Changers

Operated entirely by hand, these changers rely on direct human input to remove and insert dental burs. They are the most basic form of bur-changing technology and are widely used in general dental practices.

Advantages
  • Affordable and cost-effective
  • Simple design with minimal mechanical complexity
  • No power or electrical requirements
  • Easy to maintain and clean
  • Ideal for low-volume practices
Limitations
  • Slower operation increases chair time
  • Higher risk of hand fatigue during prolonged use
  • Potential for inconsistent bur seating
  • Requires more manual dexterity
  • Less ergonomic for frequent use

Best for: General dentistry, solo practitioners, clinics with limited budgets

Semiautomatic Dental Bur Changers

These systems combine manual initiation with automated execution. The operator starts the process (e.g., pressing a button or lever), and the device automatically ejects or inserts the bur using internal mechanisms.

Advantages
  • Balances speed and affordability
  • Reduces hand strain compared to manual models
  • More consistent bur placement
  • Requires minimal training
  • Greater efficiency than fully manual systems
Limitations
  • Still requires user input to trigger changes
  • Higher cost than manual changers
  • May require periodic calibration
  • Limited automation compared to full automatics

Best for: Mid-volume practices, multi-operator clinics, specialty dentistry with moderate bur changes

Automatic Dental Bur Changers

These advanced systems operate independently, detecting when a bur needs changing and performing the task without any manual intervention. They are often integrated into high-end dental units or robotic-assisted systems.

Advantages
  • Fastest and most efficient operation
  • Maximizes patient throughput
  • Highly consistent and precise
  • Minimizes cross-contamination risk
  • Seamless integration with digital workflows
Limitations
  • Significantly higher initial investment
  • Requires specialized maintenance
  • Dependent on power and software systems
  • Limited availability in some regions
  • May require technician support for repairs

Best for: High-volume clinics, specialty centers, teaching hospitals, digital dentistry environments

Smart & IoT-Enabled Changers

An emerging category featuring connectivity, usage tracking, and predictive maintenance. These changers log bur usage, monitor wear, and alert staff when replacements are needed.

Advantages
  • Real-time usage analytics
  • Predictive maintenance alerts
  • Inventory management integration
  • Remote diagnostics and updates
  • Enhanced traceability for compliance
Limitations
  • Premium pricing
  • Requires network connectivity
  • Data privacy considerations
  • Dependence on software stability

Best for: Advanced digital practices, corporate dental chains, research and training facilities

Type Operation Level Speed Cost Best For
Manual Full Human Control Slow $ General practice, budget-conscious clinics
Semiautomatic Partial Automation Moderate $$ Mid-volume practices, specialty clinics
Automatic Full Automation Fast $$$ High-demand environments, digital workflows
Smart/IoT Intelligent Automation Fast + Predictive $$$$ Advanced practices, data-driven operations

Expert Tip: When upgrading from manual to automated systems, consider compatibility with existing handpieces and burs. Many automatic changers are brand-specific, so verify integration before purchasing to avoid workflow disruptions.

Durability and Materials for a Dental Bur Changer

The effectiveness of a dental bur changer is closely tied to its durability and the materials used in its construction. As a critical instrument in clinical dentistry, it must withstand repeated use, rigorous sterilization protocols, and constant exposure to moisture, organic matter, and mechanical stress. The choice of material directly impacts the device’s lifespan, resistance to wear, ease of cleaning, and biocompatibility. Given that these tools frequently come into contact with bodily fluids and require regular sterilization—often involving autoclaving at high temperatures (121–134°C)—only materials with exceptional thermal stability, corrosion resistance, and mechanical strength are suitable for long-term use.

Key Material Requirements for Dental Bur Changers

  • Autoclavability: Must endure repeated high-pressure steam sterilization without degradation.
  • Corrosion Resistance: Should resist oxidation and chemical breakdown from disinfectants and oral fluids.
  • Mechanical Strength: Needs to resist deformation, wear, and fatigue from repeated mechanical operation.
  • Biocompatibility: Materials must be non-toxic and safe for use in clinical environments.
  • Surface Smoothness: Easy to clean and minimize bacterial adhesion.
  • Stainless Steel

    Stainless steel is the most widely used material in dental instrument manufacturing, including bur changers, due to its excellent balance of strength, durability, and sterilization compatibility. Composed primarily of iron, chromium (at least 10.5%), and nickel, it forms a passive oxide layer that resists corrosion and staining—even after repeated autoclaving cycles.

    Its high tensile strength ensures resistance to mechanical stress during bur insertion and removal, while its smooth surface finish allows for easy cleaning and minimizes microbial retention. Common grades like 304 and 316L stainless steel are especially favored in medical applications for their superior corrosion resistance and biocompatibility. Additionally, stainless steel is cost-effective and recyclable, making it ideal for high-volume use in busy dental clinics.

    High-Strength Ceramics

    Advanced ceramics such as zirconia (zirconium dioxide) and alumina (aluminum oxide) are increasingly explored for precision dental instruments due to their exceptional hardness, wear resistance, and chemical inertness. These materials can maintain dimensional stability over time, reducing the risk of mechanical failure in high-precision mechanisms like bur changers.

    While traditional ceramics are brittle, modern high-strength variants are engineered to resist cracking and chipping under controlled stress. They also exhibit excellent thermal stability and are non-conductive, which can be beneficial in certain electronic or sensor-integrated devices. However, their higher cost and susceptibility to fracture under impact limit widespread adoption. When used, they are typically reserved for specialized or high-end instruments where precision and longevity are paramount.

    Aluminum Alloys

    Lightweight aluminum alloys—such as 6061 and 7075—are occasionally used in non-critical components of dental handpieces and accessory tools. These alloys offer a favorable strength-to-weight ratio, good machinability, and moderate corrosion resistance, especially when anodized.

    While not as durable or heat-resistant as stainless steel, aluminum alloys are suitable for housings or ergonomic handles where weight reduction improves user comfort during prolonged procedures. However, they are generally not recommended for direct contact parts or components exposed to autoclaving, as repeated high-temperature cycles can degrade the material or compromise surface integrity. Their use in bur changers is therefore limited to secondary structural elements rather than load-bearing or sterilization-prone zones.

    Fiber-Reinforced Plastics

    Polymers reinforced with glass or carbon fibers—such as PEEK (polyether ether ketone), PEI (polyetherimide), or nylon composites—are gaining traction in medical device engineering. These materials are lightweight, electrically insulating, and resistant to many chemicals and moisture.

    In dental applications, they may be used in non-sterilizable components or disposable parts. While some high-performance thermoplastics can withstand moderate heat, most fiber-reinforced plastics cannot endure standard autoclaving temperatures without warping or degrading. As a result, they are typically avoided in reusable bur changers unless specifically engineered for thermal resilience. Their primary advantages lie in design flexibility, reduced manufacturing cost, and vibration damping—making them suitable for prototypes or low-stress applications.

    Material Heat Resistance (Autoclavable) Corrosion Resistance Strength & Durability Typical Use in Bur Changers
    Stainless Steel Excellent (up to 135°C) Excellent Very High Primary structural and functional components
    High-Strength Ceramics Excellent Excellent High (but brittle) Specialized precision parts
    Aluminum Alloys Fair (limited cycles) Good (with coating) Moderate Ergonomic housings, non-critical parts
    Fiber-Reinforced Plastics Poor to Moderate Good (chemical) Moderate (impact-sensitive) Disposable or low-stress accessories

    Best Practices for Material Selection and Maintenance

  • Prioritize Autoclavable Materials: Always select bur changers made from materials certified for repeated sterilization, preferably stainless steel.
  • Avoid Mixed Materials: Devices combining incompatible materials may suffer galvanic corrosion or differential expansion during sterilization.
  • Inspect Regularly: Check for signs of pitting, discoloration, or mechanical wear that could compromise function or hygiene.
  • Follow Manufacturer Guidelines: Adhere strictly to cleaning and sterilization protocols to extend the life of the instrument.
  • Replace When Necessary: Even durable materials degrade over time; replace worn components before they fail during clinical use.
  • Important: Using non-autoclavable or substandard materials in dental bur changers poses serious risks, including cross-contamination, mechanical failure, and patient safety hazards. Always ensure that instruments meet ISO 13485 and FDA standards for medical devices. Proper material selection not only ensures compliance with infection control protocols but also enhances clinical efficiency and instrument longevity.

    How to Choose the Right Dental Bur Changer

    Selecting the ideal dental bur changer is a crucial decision that impacts clinical efficiency, procedural accuracy, and long-term operational costs. With various models available—ranging from manual to fully automatic—practitioners must evaluate multiple factors to ensure the chosen system aligns with their practice’s workflow, patient volume, and budget. Unlike general equipment like batteries or saunas, bur changers are specialized tools that directly affect treatment speed and ergonomics. The right choice enhances precision, reduces hand fatigue, and supports consistent sterility standards.

    Dental Practice Type and Procedures

    The nature of your dental practice significantly influences the type of bur changer that will be most effective. Different specialties have unique demands based on the frequency, complexity, and duration of procedures.

    • Restorative dentistry (e.g., fillings, crowns) often requires frequent bur changes, making automatic or semi-automatic changers highly beneficial for maintaining workflow continuity.
    • Endodontic practices may benefit from precision changers compatible with delicate files and small-diameter burs, ensuring secure retention and minimizing slippage.
    • Prosthodontics and implantology involve multi-step procedures with specialized burs; systems with quick-swap mechanisms reduce chair time and improve procedural accuracy.
    • General or pediatric dentistry with lower bur turnover may find manual changers sufficient, especially when cost and simplicity are priorities.

    Key insight: High-mix practices benefit from changers with broad compatibility across bur types and shank sizes (e.g., ISO 170, 300, 330).

    Volume of Procedures

    The daily number of dental procedures directly correlates with the need for speed, reliability, and durability in a bur changer system.

    • High-volume clinics (15+ procedures/day) should invest in automatic changers that reduce instrument exchange time by up to 70%, enhancing throughput and reducing clinician fatigue.
    • Semi-automatic systems offer a balance—faster than manual options but more affordable than full automation—ideal for mid-volume practices (8–15 procedures/day).
    • Low-volume or specialty practices (fewer than 8 procedures/day) can operate efficiently with manual changers, which are cost-effective and easy to maintain.
    • High-frequency use also increases wear, so durability and ease of replacement parts become critical considerations.

    Efficiency tip: In high-volume settings, even a 5-second reduction per bur change can save over 2 hours per week.

    Cost Considerations and ROI

    While initial price is important, long-term value should guide purchasing decisions. A comprehensive cost analysis includes not only the purchase price but also maintenance, lifespan, and impact on clinical productivity.

    • Manual changers typically cost $50–$150 and are ideal for budget-conscious or low-use practices. However, they may slow down procedures and increase hand strain over time.
    • Semi-automatic systems range from $300–$800 and offer a strong return on investment (ROI) in moderate-use settings by improving speed and reducing errors.
    • Automatic changers can cost $1,000–$3,000 but are justified in high-volume or specialty clinics where time savings and consistency are paramount.
    • Consider warranty length, availability of replacement parts, and service support—premium brands often offer 2–5 year warranties reflecting build quality.

    Smart investment: Calculate potential time savings and reduced staff fatigue when evaluating higher-priced models.

    Material Quality and Durability

    The materials used in a bur changer affect its performance, longevity, and compatibility with sterilization protocols. Given the rigorous autoclave cycles in dental offices, only high-grade materials should be considered.

    • Stainless steel is the industry standard for its corrosion resistance, strength, and ability to withstand repeated high-temperature sterilization (up to 135°C).
    • High-strength ceramics are used in premium models for their thermal stability and resistance to wear, especially in automatic mechanisms.
    • Heat-resistant polymers may be used in non-critical components to reduce weight while maintaining dimensional stability.
    • Look for changers with anti-microbial coatings or smooth surfaces that minimize crevices where debris can accumulate.

    Critical note: Poor material quality can lead to bur slippage, inaccurate seating, or premature failure after repeated autoclaving.

    Professional Recommendation: For most general practices, a semi-automatic bur changer made from medical-grade stainless steel offers the best balance of cost, efficiency, and durability. It reduces procedural delays without the high upfront cost of full automation. Always verify compatibility with your handpiece model and bur types before purchasing. When in doubt, opt for modular systems that allow future upgrades as practice needs evolve.

    Practice Profile Recommended Changer Type Material Specification Estimated Lifespan Price Range (USD)
    General Dentistry (Low Volume) Manual Stainless Steel with Polymer Grip 2–4 years $50–$150
    Family Practice (Moderate Volume) Semi-Automatic Full Stainless Steel Mechanism 5–7 years $300–$800
    Specialty Clinic (High Volume) Automatic Stainless Steel + Ceramic Components 7–10 years $1,000–$3,000
    University or Teaching Facility Semi-Automatic (Modular) Durable Alloy with Interchangeable Heads 6–8 years $500–$1,200

    Additional Considerations

    • Compatibility: Ensure the changer is compatible with your handpieces (e.g., friction grip, latch-type) and common bur shank sizes (e.g., ISO 170, 300).
    • Ergonomics: Look for lightweight, well-balanced designs that reduce hand and wrist strain during prolonged use.
    • Sterilization Safety: All components should be autoclavable at standard dental sterilization temperatures (121–135°C) without degradation.
    • No-Slip Mechanism: Precision-engineered collets or chucks ensure secure bur retention, preventing wobbling or ejection during high-speed operation.
    • Brand Support: Choose manufacturers that offer technical support, replacement parts, and clear user manuals to ensure long-term usability.

    Maintenance and Repair of a Dental Bur Changer

    Proper maintenance of dental bur changers is essential for maximizing equipment longevity, ensuring consistent clinical performance, and minimizing long-term operational costs. A well-maintained bur changer not only reduces the frequency of costly repairs but also lowers the total cost of ownership by extending the lifespan of critical components. For dental practices, promoting regular maintenance to clients can also open opportunities for additional service offerings, improving client retention and practice revenue. Implementing a preventive (or scheduled) maintenance program helps avoid unexpected equipment failures, which can disrupt patient appointments and compromise treatment efficiency. Preventive maintenance is based on the performance metrics of system components—such as actuation speed, alignment accuracy, and sensor responsiveness—and requires a structured management approach. Additionally, proper handling, cleaning, and sterilization of consumables like dental burs are crucial to prevent contamination and premature wear of the changer mechanism.

    Safety and Compliance Note: Always follow infection control protocols and manufacturer guidelines when handling dental equipment. Use only approved cleaning agents and sterilization methods to avoid material degradation or patient safety risks.

    Cleaning Requirements for Dental Bur Changers

    Cleaning—defined as the physical removal of debris, organic residue, and microbial contaminants—is a foundational step in maintaining the functionality and hygiene of dental bur changers. Accumulated debris can interfere with mechanical operations, cause jamming, and promote bacterial growth, especially in automated systems with moving parts.

    • Frequency: Clean after every patient use or at least once daily in high-volume practices.
    • Manual Changers: Wipe down external surfaces with a lint-free cloth dampened with isopropyl alcohol (70–90%). Avoid soaking plastic components to prevent cracking or clouding.
    • Metal Components: Can typically be sterilized using an autoclave (134°C, 20–30 minutes) if labeled as autoclavable. Always verify compatibility with the manufacturer’s specifications.
    • Plastic Components: Should never be autoclaved unless explicitly rated for high-temperature sterilization. Instead, clean with medical-grade alcohol wipes or enzymatic cleaners, then air-dry completely before reuse.
    • Cleaning Agents: Use non-corrosive, non-abrasive solutions. Avoid bleach, acetone, or ammonia-based cleaners, as they can degrade seals, housings, and electronic components.
    • Automated Systems: Follow the manufacturer’s recommended cleaning cycle. Some models include self-cleaning functions or require periodic internal debris clearing via maintenance ports.

    Expert Tip: Inspect the bur retention mechanism regularly for residue buildup. A clogged chuck or collet can lead to improper bur seating, reducing cutting efficiency and increasing the risk of bur ejection during use.

    Maintenance Schedule and Inspection Protocol

    A structured maintenance schedule ensures that potential issues are identified and addressed before they lead to system failure. This proactive approach is especially critical for advanced automatic bur changers, which rely on precision sensors, actuators, and control systems.

    • Daily: Visual inspection for debris, proper alignment, and smooth operation. Perform basic cleaning as outlined above.
    • Weekly: Check for wear on moving parts such as gears, sliders, and grippers. Test sensor responsiveness (e.g., bur detection, position feedback).
    • Monthly: Inspect seals, gaskets, and O-rings for cracks, deformation, or loss of elasticity. Replace if signs of wear are present to prevent contamination ingress.
    • Quarterly: Professional servicing recommended. Technicians should calibrate sensors, verify actuator performance, and check firmware/software updates if applicable.
    • Lubrication: Only use manufacturer-approved, medical-grade lubricants on moving parts. Over-lubrication can attract dust and debris, leading to clogs.
    • Documentation: Maintain a log of all maintenance activities, including dates, findings, and actions taken. This supports warranty claims and regulatory compliance.
    Maintenance Task Frequency Responsible Party Tools/Supplies Needed
    External cleaning and disinfection Daily Clinical staff Alcohol wipes, lint-free cloth, enzymatic cleaner
    Internal debris inspection Weekly Trained assistant or technician Flashlight, inspection mirror, compressed air
    Seal and gasket inspection Monthly Practice manager or technician Replacement seals, magnifying glass
    System calibration and diagnostics Quarterly Manufacturer-certified technician Diagnostic software, calibration tools
    Lubrication of moving parts As needed (every 3–6 months) Technician Medical-grade lubricant, applicator

    Repair Procedures and Best Practices

    Repair procedures refer to the systematic steps taken to restore a malfunctioning dental bur changer to full operational status. Due to the precision engineering involved, many repairs—especially those involving internal electronics, sensors, or firmware—should only be performed by the manufacturer or an authorized service provider.

    • Common Minor Repairs: Replacement of worn seals, realignment of mechanical arms, or resetting jammed bur trays can often be handled in-house with proper training.
    • Major Repairs: Issues such as sensor failure, motor burnout, or software glitches require professional intervention. Attempting DIY fixes may void warranties and compromise patient safety.
    • Training and Certification: Dental professionals and support staff should receive training on basic troubleshooting and maintenance protocols. This includes recognizing early warning signs like delayed actuation, misaligned bur placement, or error codes.
    • Preventive Replacement: Proactively replace high-wear components (e.g., springs, grippers) before they fail. This minimizes downtime and prevents cascading damage.
    • Downtime Management: Keep a backup manual bur changer or handpieces available during repairs to maintain clinical workflow.

    Pro Tip: Establish a service agreement with the manufacturer or a certified dental equipment technician. Scheduled checkups and priority repair access can significantly reduce unexpected disruptions and extend equipment life.

    Conclusion and Recommendations

    Effective maintenance of dental bur changers combines routine cleaning, scheduled inspections, and timely repairs. By implementing a comprehensive preventive maintenance program, dental practices can enhance equipment reliability, reduce repair costs, and ensure a safe, efficient clinical environment. Educating staff on proper handling and involving clients in maintenance discussions can further strengthen service delivery and practice reputation. Always consult the manufacturer’s manual for model-specific guidance and never compromise on sterilization or safety standards.

    Frequently Asked Questions About Dental Bur Changers

    Q1: How does one know whether a dental bur changer is proper for their practice?

    Selecting the right dental bur changer is crucial for maintaining efficiency, safety, and workflow continuity in your clinic. The ideal choice depends on several key factors unique to your practice:

    • Practice Size: Solo practitioners may benefit from compact, manual changers, while larger clinics with multiple operators might require semi-automatic or automatic systems to keep pace with high demand.
    • Type of Procedures: Practices specializing in endodontics, prosthodontics, or oral surgery often use a wide variety of burs. A versatile changer that supports quick, secure transitions between bur types enhances precision and reduces downtime.
    • Procedure Volume: High-volume practices should consider durable, fast-acting changers that minimize handpiece wear and reduce the risk of repetitive strain injuries.
    • Budget and ROI: While initial cost is a consideration, long-term value—such as reduced bur breakage, lower maintenance, and improved sterilization compatibility—should guide purchasing decisions.
    • Ergonomics and Staff Comfort: A well-designed changer reduces hand fatigue and supports consistent, accurate bur placement, contributing to clinician comfort and patient safety.

    Consulting product specifications, reading peer reviews, and testing units during dental exhibitions or through trial programs can help ensure the selected changer aligns with your clinical needs and operational goals.

    Q2: Are materials in dental changers essential for sterilization capable of bearing heat?

    Yes, materials used in dental bur changers must be compatible with standard sterilization protocols, particularly autoclaving, which involves high temperatures (typically 121–134°C) and pressure.

    • Stainless Steel: Most high-quality changers use medical-grade stainless steel (e.g., 304 or 316L), which resists corrosion, maintains structural integrity under repeated heat cycles, and prevents contamination.
    • Ceramic Components: Some advanced changers incorporate ceramic parts for insulation or precision mechanisms. These are engineered to withstand thermal stress without cracking or degrading.
    • Heat-Resistant Polymers: In certain semi-automatic models, select internal components may use autoclavable polymers designed to endure repeated sterilization without warping or releasing toxins.

    Always verify manufacturer guidelines to ensure the entire unit—or removable parts—is labeled as autoclavable. Non-sterilizable changers pose infection control risks and are unsuitable for clinical environments.

    Q3: When should dental changers undergo professional checks or servicing?

    Regular maintenance is essential to ensure the reliability, safety, and longevity of dental bur changers. The frequency of inspections depends on usage intensity and clinical demands:

    • Monthly Visual Inspections: Clinicians should check for signs of wear, such as bur slippage, misalignment, or resistance during engagement. Look for debris buildup or corrosion, especially in latch mechanisms.
    • Quarterly Professional Servicing: Recommended for most practices, especially those with moderate to heavy usage. A certified technician can disassemble, clean, lubricate moving parts, and test torque accuracy.
    • Usage-Based Maintenance: High-traffic clinics (e.g., dental schools or specialty centers) may benefit from rotating service schedules—e.g., servicing one-third of units every month—to prevent unexpected failures.
    • After Sterilization Cycles: Monitor changers exposed to frequent autoclaving, as thermal expansion can gradually affect metal tolerances over time.

    Keeping a maintenance log helps track performance trends and supports warranty claims. Prompt servicing at the first sign of malfunction ensures consistent performance and patient safety.

    Q4: Why are dental changers like semi-automatic and automatic ones expensive?

    The higher cost of semi-automatic and automatic dental bur changers reflects their advanced engineering, enhanced functionality, and integration of precision technology:

    Feature Manual Changers Semi-Automatic & Automatic Changers
    Internal Mechanism Simple mechanical latch or screw system Motorized actuators, micro-sensors, and electronic controls
    Speed & Efficiency Slower; requires manual force and alignment Fast, consistent bur changes with minimal user input
    Durability & Precision Good, but prone to user error High precision with torque control to prevent over-tightening
    Maintenance Needs Low, but frequent manual checks needed Higher initial cost but optimized long-term performance
    Ideal For Low-volume or budget-conscious practices Specialty clinics, teaching institutions, high-throughput offices

    The integration of smart sensors ensures proper bur seating, reducing the risk of intraoperative dislodgement. While the upfront investment is greater, these systems improve workflow efficiency, reduce handpiece wear, and enhance overall clinical safety—making them cost-effective in demanding environments.

    Q5: Do dental burs and changers wear out quickly?

    Not necessarily. With proper care, both dental burs and changers can have a long service life. However, their longevity depends heavily on handling, sterilization practices, and usage patterns:

    • Proper Sterilization: Following manufacturer-recommended autoclave settings (time, temperature, cycle type) prevents premature degradation of metal components and seals.
    • Avoiding Mechanical Damage: Dropping changers or forcing burs into misaligned slots can cause internal damage or deformation, leading to inconsistent performance.
    • Regular Cleaning: Residue from saliva, blood, or cleaning agents can accumulate in mechanisms. Routine cleaning after each sterilization cycle prevents corrosion and jamming.
    • Bur Quality: Using high-quality, compatible burs reduces stress on the changer mechanism. Poorly manufactured burs may have inconsistent shank dimensions, increasing wear.
    • Expected Lifespan: A well-maintained manual changer can last 3–5 years or more. Semi-automatic units may require component replacements (e.g., motors, sensors) after several thousand cycles but remain functional with servicing.

    In summary, dental bur changers are designed for durability. Their lifespan is maximized not by infrequent use, but by consistent, correct usage and proactive maintenance—ensuring reliable performance and patient safety over time.